1. Heating Element - Glow - Wire : Nickel / Chromium ( Ni/Cr
- 80:20 ) wire of 4 mm dia. with a shape as per Standard.
2. Temperature Sensor - Thermocouple : Fine Wire of
Cr / Al of 0.5 mm dia. located in 0.6 mm dia. pocket hole
in Glow - Wire, to measure Glow - Wire temperature. Sheath
resistant to 1000 deg. C.
3. Temperature Control : Proportional Temperature
controller - 3& 1/2 Digit, 1 deg. C resolution, with ambient
temperature compensation, (200 deg. C per min. ramp).
4. Temperature Range : Adjustable up to 960 deg. C.
5. Time Controller :
a) Digital Preset Timer - 3 Digits, 0-99.9sec.
b) Digital Time Interval Meter - 0to 99.9 sec.
6. Carriage : A Mounting Tray, Universally adjustable
SS Perforated Tray on a Trolley is provided to mount the Specimen.
7. Penetration Depth : Mechanically restricted to
7 mm only.
8. Sample Loading : Test Sample contact force against
the GLOW-WIRE pre-loaded to 0.8 to 1.2 N.
9. Sample Size : 180 mm x 150mm max. & 15mm x
15mm min., Thickness 10 mm to 80 mm
10. Safety : Emergency Switch, MCB & Fuses.
11. Dimensions : 600 mm W x 300 mm D x 610 mm H, overall.
12. Supply : 230 V AC, 50 Hz, 1 Ph, 500 VA.
|